Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
J Environ Manage ; 353: 120248, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38325280

RESUMO

Sensor data and agro-hydrological modeling have been combined to improve irrigation management. Crop water models simulating crop growth and production in response to the soil-water environment need to be parsimonious in terms of structure, inputs and parameters to be applied in data scarce regions. Irrigation management using soil moisture sensors requires them to be site-calibrated, low-cost, and maintainable. Therefore, there is a need for parsimonious crop modeling combined with low-cost soil moisture sensing without losing predictive capability. This study calibrated the low-cost capacitance-based Spectrum Inc. SM100 soil moisture sensor using multiple least squares and machine learning models, with both laboratory and field data. The best calibration technique, field-based piece-wise linear regression (calibration r2 = 0.76, RMSE = 3.13 %, validation r2 = 0.67, RMSE = 4.57 %), was used to study the effect of sensor calibration on the performance of the FAO AquaCrop Open Source (AquaCrop-OS) model by calibrating its soil hydraulic parameters. This approach was tested during the wheat cropping season in 2018, in Kanpur (India), in the Indo-Gangetic plains, resulting in some best practices regarding sensor calibration being recommended. The soil moisture sensor was calibrated best in field conditions against a secondary standard sensor (UGT GmbH. SMT100) taken as a reference (r2 = 0.67, RMSE = 4.57 %), followed by laboratory calibration against gravimetric soil moisture using the dry-down (r2 = 0.66, RMSE = 5.26 %) and wet-up curves respectively (r2 = 0.62, RMSE = 6.29 %). Moreover, model overfitting with machine learning algorithms led to poor field validation performance. The soil moisture simulation of AquaCrop-OS improved significantly by incorporating raw reference sensor and calibrated low-cost sensor data. There were non-significant impacts on biomass simulation, but water productivity improved significantly. Notably, using raw low-cost sensor data to calibrate AquaCrop led to poorer performances than using the literature. Hence using literature values could save sensor costs without compromising model performance if sensor calibration was not possible. The results suggest the essentiality of calibrating low-cost soil moisture sensors for crop modeling calibration to improve crop water productivity.


Assuntos
Solo , Água , Solo/química , Simulação por Computador , Biomassa , Estações do Ano
2.
Sensors (Basel) ; 20(2)2020 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-31936425

RESUMO

Soil volumetric water content ( V W C ) is a vital parameter to understand several ecohydrological and environmental processes. Its cost-effective measurement can potentially drive various technological tools to promote data-driven sustainable agriculture through supplemental irrigation solutions, the lack of which has contributed to severe agricultural distress, particularly for smallholder farmers. The cost of commercially available V W C sensors varies over four orders of magnitude. A laboratory study characterizing and testing sensors from this wide range of cost categories, which is a prerequisite to explore their applicability for irrigation management, has not been conducted. Within this context, two low-cost capacitive sensors-SMEC300 and SM100-manufactured by Spectrum Technologies Inc. (Aurora, IL, USA), and two very low-cost resistive sensors-the Soil Hygrometer Detection Module Soil Moisture Sensor (YL100) by Electronicfans and the Generic Soil Moisture Sensor Module (YL69) by KitsGuru-were tested for performance in laboratory conditions. Each sensor was calibrated in different repacked soils, and tested to evaluate accuracy, precision and sensitivity to variations in temperature and salinity. The capacitive sensors were additionally tested for their performance in liquids of known dielectric constants, and a comparative analysis of the calibration equations developed in-house and provided by the manufacturer was carried out. The value for money of the sensors is reflected in their precision performance, i.e., the precision performance largely follows sensor costs. The other aspects of sensor performance do not necessarily follow sensor costs. The low-cost capacitive sensors were more accurate than manufacturer specifications, and could match the performance of the secondary standard sensor, after soil specific calibration. SMEC300 is accurate ( M A E , R M S E , and R A E of 2.12%, 2.88% and 0.28 respectively), precise, and performed well considering its price as well as multi-purpose sensing capabilities. The less-expensive SM100 sensor had a better accuracy ( M A E , R M S E , and R A E of 1.67%, 2.36% and 0.21 respectively) but poorer precision than the SMEC300. However, it was established as a robust, field ready, low-cost sensor due to its more consistent performance in soils (particularly the field soil) and superior performance in fluids. Both the capacitive sensors responded reasonably to variations in temperature and salinity conditions. Though the resistive sensors were less accurate and precise compared to the capacitive sensors, they performed well considering their cost category. The YL100 was more accurate ( M A E , R M S E , and R A E of 3.51%, 5.21% and 0.37 respectively) than YL69 ( M A E , R M S E , and R A E of 4.13%, 5.54%, and 0.41, respectively). However, YL69 outperformed YL100 in terms of precision, and response to temperature and salinity variations, to emerge as a more robust resistive sensor. These very low-cost sensors may be used in combination with more accurate sensors to better characterize the spatiotemporal variability of field scale soil moisture. The laboratory characterization conducted in this study is a prerequisite to estimate the effect of low- and very low-cost sensor measurements on the efficiency of soil moisture based irrigation scheduling systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...